SKU: 37538000A in-line fuse switch-disconnector 600 A
QUADRON 185Power
size 3, 1-pole switchable
V-clamp 50-300 mm²
terminal body alu, pressure piece brass
prewired with 3x measuring transformers 600 A / 333 mV, accuracy class 1, with 6-pole plug connectiof
ufor busbars 30, 40, 60, 80, 100, 120 x 10
SKU: 32784000A busbar adapter 1220 A
EQUES 185Power
300 x 652, connection top / bottom, screw connection 
for ABB Tmax T7, XT7 (1250 A), Emax E1.2 (1250 A), Siemens 3VA27 (1250 A)
for busbars 30, 40, 60, 80, 100, 120 x 10
not suitable for systems with CrossLink protection modules
SKU: 32785000A busbar adapter 1000 A
EQUES 185Power
300 x 652, connection top / bottom, screw connection 
for ABB Tmax T6, XT6 (1000 A), T7, XT7 (1000 A), Emax E1.2 (1000 A), Siemens 3VA27 (1000 A)
for busbars 30, 40, 60, 80, 100, 120 x 10
not suitable for systems with CrossLink protection modules
SKU: 32786000A busbar adapter 800 A
EQUES 185Power
300 x 652, connection top / bottom, screw connection 
for ABB Tmax T6, XT6, T7, XT7 (800 A), Emax E1.2 (800 A), Siemens 3VA27 (800 A)
for busbars 30, 40, 60, 80, 100, 120 x 10
not suitable for systems with CrossLink protection modules
SKU: 32808000A busbar adapter 1320 A
EQUES 185Power
300 x 652, connection top / bottom, screw connection 
for ABB Tmax T7, XT7 (1600 A), Emax E1.2 (1600 A), Siemens 3VA27 (1600 A)
for busbars 30, 40, 60, 80, 100, 120 x 10
not suitable for systems with CrossLink protection modules
SKU: 33627000A NH in-line switch-disconnector-fuse size 00
QUADRON 185Power Speed
high version, connection top M8
tall version, outgoing terminals at the top, screw connection
operator independent switching (snap-action mechanism)
for busbars 30, 40, 60, 80, 100, 120 x 10
not suitable for systems with CrossLink protection modules
SKU: 37520000B in-line fuse switch-disconnector 160 A
QUADRON 185Power
Size 00, 3-pole switchable
high version with V-clamp 95 mm²
terminal body alu, pressure piece brass
prewired with 3x measuring transformers 150 A / 333 mV, accuracy class 1, with 6-pole plug connectiof
ufor busbars 30, 40, 60, 80, 100, 120 x 10
SKU: 37525000B in-line fuse switch-disconnector 160 A
QUADRON 185Power
Size 00, 1-pole switchable
high version with V-clamp 95 mm²
terminal body alu, pressure piece brass
prewired with 3x measuring transformers 150 A / 333 mV, accuracy class 1, with 6-pole plug connectiof
ufor busbars 30, 40, 60, 80, 100, 120 x 10
SKU: 37520000A in-line fuse switch-disconnector 160 A
QUADRON 185Power
Size 00, 3-pole switchable
high version with V-clamp 95 mm²
terminal body alu, pressure piece brass
prewired with 3x measuring transformers 150 A / 333 mV, accuracy class 0.5, with 6-pole plug connectf
ufor busbars 30, 40, 60, 80, 100, 120 x 10
SKU: 37525000A in-line fuse switch-disconnector 160 A
QUADRON 185Power
Size 00, 1-pole switchable
high version with V-clamp 95 mm²
terminal body alu, pressure piece brass
prewired with 3x measuring transformers 150 A / 333 mV, accuracy class 0.5, with 6-pole plug connectf
ufor busbars 30, 40, 60, 80, 100, 120 x 10